Analytical Instrument

HORIBA : X-Ray Fluoresecence

SLFA-20 X-ray Fluorescence Sulfur-in-Oil Analyzers

  • Measuring the new low sulfur fuels, diesel

  • Ultra compact and light weight (Easy to carry and ideally suited for on-site analysis
  • SLFA-UV 21A X-ray Fluorescence Sulfur-in-Oil Analyzers

  • Recflective filter for high sensitivity

  • Detection limits 30 ppb

  • Confirms to the standard “ASTM D5453”
  • XGT-5000/5700WR

  • Increases detection sensitivity with a new optical system 3mm X-ray irradiation diameter and dual filter system

  • Can be use to analyze hazardous elements in Ni and Sn plating
  • MESA-500W

  • MESA-500W handles Solid, liquid and powder Samples with “One touch” Fully automatic operation That requires no specialized Operator knowledge.
  • SLFA-2100/2800 X-ray Fluorescence Sulfur-in-Oil Analyzers

  • Measuring the new low sulfur fuels, diesel and RFG.

  • Detection Limit 5 ppm.

  • Compact high-power X-ray tube, and without helium purge, to achieve high repeatability
  • XGT-7000/7200V

  • Unparalleled elemental analysis performance with spatial resolutions down to 10 µm.

  • A complete elemental analysis solution, including qualitative and quantitative characterisation
  • XGT-1000/1700WR RoHS and ELV Analysis

  • Widely used for fast, non-destructive screening of manufacturing materials and parts for RoHS and ELV
    compliancy.


  • HORIBA : Induced Couple Plasma (ICP)

    JY 2000-2

  • The photomultiplier tube (PMT) with High Dynamic Detection system (HDD)

  • Extended and continuous spectral range
    160 – 800 nm ( Option 120-800 nm)

  • Total Plasma View based on a vertical torch 6 mm.
  • ULTIMA Family

  • The photomultiplier tube (PMT), which combines detection and amplification, but which is a single-channel detector.

  • Wavelength 120 – 800 nm.

  • The best resolution with the 1 meter.

  • ICP - ACTIVA Family

  • Advance CCD detection

  • Extended and continuous spectral range

  • : 160-800 nm for ACTIVA-S
    : 120-800 nm for ACTIVA-M
  • Total Plasma View based on a vertical torch 6mm.
  • HORIBA : Elemental Analyzer

    EMIA-V Series Carbon/Sulfer Combustion Analyzer

    - Determine the carbon and sulfur contained in steels, nonferrous metals, steel alloys, special metals, inorganic iron ores, etc.

    EMGA Oxygen/Nitrogen/Hydrogen Combustion Analyzer

    - High accuracy and repeatability suiting to cutting-edge technology's R&D as well as quality control in the market of steel.

    FT-730 FTIR Spectrometer

  • The Fourier Transform Infrared and provide high performance measurement to detect the functional group of organic subatnces.

  • HORIBA : Particle Size Analysis

    Automatic Polarimeter

  • Peltier-type thermostatic cell holder that does not require the use of water.

  • High response speed and high resolution.

  • Data saved USB memory.
  • LA-950

  • Base on Mie Scattering Principle.

  • Measurement ranges from 0.01 - 3000 mm.
  • LA-300

  • Base on Mie Scattering Principla

  • DMeasurment ranges from 0.1 - 600 mm
  • SZ-100

  • Series of nano-particle size analyzer is able to provide information on particle size, molecular weight(MW) and zeta potential(ZP).
  • HORIBA : Atomic Emission Spectroscopy

    GD-Profiler Discover a Whole new World of information

  • Fast simulataneous analysis of all elements of interest including the gases nitrogen, oxygen, hydrogen, and chlorine on depth and bulk analysis.

  • Ideal tool for thin film characterization and process studies
  • 3D Metal with CCD technology

  • Dedicated to the metal industry and capable of bulk analysis of metals and depth profile of thick layers (heat treatment, Zn coatings, electroplating) .
  • PG Instruments : Spectrophotometer

    Atomic Absorption Spectrophotometer

  • WavFlame and graphite furnace is integrated into one instrument.

  • elength and peak selection is automatic and controlled from the software.

  • the optical temperature during the automation stage ensures the rapids heating and rapid analysis.

  • this help to extend the life of graphite tube and enhance the analytical accuracy

  • T90 UV-VIS Spectrophotometer

  • Double beam Spectrophotometer

  • Suitable for analytical applications

  • Higher level of accuracy is required

  • 8 cell holder
  • T60 UV-VIS Spectrophotometer

  • Single beam Spectrophotometer

  • Suitable for analytical applications

  • Excellent performance and stability

  • 5 or 8 cell Changer
  • T80 UV-VIS Spectrophotometer

  • Double beam Spectrophotometer

  • Suitable for analytical applications

  • Higher level of accuracy is required

  • Automatic 8 cell holder
  • T70 UV-VIS Spectrophotometer

  • Split beam ratio optic Spectrophotometer

  • Suitable for analytical applications

  • 8 cell holder
  • SRI : Gas Chromatograph

    Gas Chromatograph

  • Multiple gas analyzer

  • TOGA GC

  • BTEX GC

  • Education model

  • Customized model

  • Contact
    Kinetics Corporation Ltd. (ALB)

    388 Ratchadapisek Road, Chandrakasem,
    Chatuchak, Bangkok 10900 Thailand.
    Tel : 662-515-8932
    Fax : 662-515-8988
    E-mail : alb@kinetics.co.th
    Website : www.kinetics.co.th