AOIP Measurement

DRY BLOCKS

  • Temperature Range: +30 °C to +250 °C

  • Thermal Performance: As a liquid comparison bath Uniformity down to ±0.005 °C Cover the full range

  • Calibration volume: 65mm diameter by 160mm deep

  • Includes UKAS Certificate as Standard

  • Easy to use temperature reference, self

  • contained no further equipment necessary

  • High Capacity Block
  • HYGROFLEX

  • Temperature range up to 200 °C, 90...250 VAC supply,

  • Digital output signal RS232/RS485

  • Accuracy: Probe dependent

  • Transfer data: RS232 output

  • Display of calculated values; dew-point, mixing ratio,

  • Standard factory configuration is 4…20 mA

  • Scaling of the output range can be

  • modified from the standard 0…100 % rh and 0…100 °C
  • HYGROLAB

  • Maximum measuring range: Probe dependent; 0...100%rh, -50...+200 °C

  • Accuracy: ± 1.5% rh, ± 0.3 K

  • CE conformity EMV: EN50081-2 EN/EN50082-2

  • Number of probe inputs up to 4 channels

  • Number of probe inputs up to 8 channels

  • Number of digital input channels up to 4 channels

  • Analog input A/D resolution up to 12 bits
  • DIGITAL NETWORK TRANSMITTERS

  • Resistive temperature pro be 0.05% + 0.2°C

  • DC voltage 0.1% + 2 mV

  • Process current (0-20 mA) 0.1% + 4 μA

  • Thermocouples transmitter 0.1% + 0.3°C

  • DIN rail pluggable casings

  • 2-channel transmitters for measuring temperature

  • Scaling of each input or correction using linearization table.

  • Several power supplies available
  • PORTABLE OPTICAL PYROMETERS

  • Temperature ranges: 900...3,000 °C

  • Spectral range: channel 2 : 0.98 μm

  • Field of view: 180 : 1 (min 2.8)

  • Analog output: 1 mV/°C or 0 - 1 V RS232

  • Memory up to 5-200 measurements

  • Dual display pyrometers

  • Battery Charger: plugs into front panel of M90 to recharge Ni-Cad batteries overnight.

  • Output 12VDC, Input 220VAC
  • PROGRAMMABLE MICRO-OHMMETER

  • 4-wire resistance measurement from 0,1 µW to 200 kW with an accuracy of 0.03 % and a display over 26,000 counts.

  • Display of the measured resistance value reduced to 20°C.

  • Mains supply or rechargeable batteries.

  • Winding heating measurement.

  • Storage and analysis of 1,000 measurements

  • Measurement of heat-sensitive devices

  • Standard NFC 93050, DIN/IEC,

  • Inductive resistance measurement
  • HIGH ACCURACY SCANNER

  • 6 RTD measurement channels, 4 wire configuration or 12 voltage (thermocouples) measurement channels, 2 wire configuration or N 4 wire channels and 2 x (6 – N) 2 wire channel.

  • Temperature coefficient:± 0.005°C/°C max.

  • Fully compatible with the PHP 601

  • RS 232 connectivity

  • Metrology scanner

  • Thermocouples and RTDs
  • HYDRAULIC HAND PUMP

  • Range 0-700 bars or 0-1,000 bars.

  • Adjustable security valve to limit output pressure

  • Delivered with carrying case.

  • In option: flexible coupling with quick connection

  • Compatible with most liquids. e.g. mineral oil, distilled water

  • Pressure release valve.

  • Quick priming and pressure generation using scissor action pump

  • Large see-through reservoir with a capacity of over 100 cc.
  • POCKET THERMOMETER

  • Measurement Hold functions.

  • Display of minimum, maximum and average values.

  • Backlit Display. • 100,000 measurement memory.

  • High Accuracy: 0.02% of reading

  • TM6630 - as above - all thermocouples and RTDs

  • Data logging - on screen or PC software – 10,000 readings

  • Graphic on screen display, IP54 housing - standard connectors

  • Logging by push button, by event, or by time interval
  • DATA ACQUISITION SYSTEM DATA LOGGER

  • Modular data acquisition systems.

  • Accuracy: Thermocouples: 0.008 % RDG / RTDs: 0.01 % RDG, DC voltage: 0.008 % RDG , AC voltage: 0.3 % RDG
    Resistance: 0.01 % RDG, Strain gauges: 0.05 % RDG

  • Conversion under 600,000 counts.

  • Sampling: 100 samples/s

  • RS 232/RS 485 ASCII and MODBUS/RTU communication interfaces.

  • Relay and analogue outputs
  • DATA ACQUISITION SYSTEM SA32

  • Can handle up to 32 measurement channels.

  • Internal battery, mains supply and 11 V to 28 VDC.

  • Sampling: 100 samples/s

  • OUTPUT channels: 2 relay outputs + 0 / 2.5 V recopy analog output

  • Accuracy: Thermocouples: 0.008 % RDG , RTDs: 0.01 % RDG, DC voltage: 0.008 % RDG, AC voltage: 0.3 % RDG,
    Resistance: 0.01 % RDG

  • Communication modes: RS 485 and RS 232
  • TRANSMISSION SYSTEM

  • Measurement of 4-20mA output from pressure, pH, humidity sensors

  • Thermocouple measurement for high temperature

  • System is able to manage up to 256 modules thanks to link multi-channel.

  • 2 channels for process measurement: voltage and current

  • 2 channels for thermocouples

  • 2 channels for resistive probes

  • 2 relays outputs, triggering from other T2RN's alarm thresholds
  • UNIGAS 1000 / 2000 / 3000

  • Application: Service/maintenance companies, Gas distribution companies, Boiler manufacturers and Government , HVAC market, Heating engineers and Plumbers

  • Accordance with DIN33962

  • A flue gas analyser, an emissions monitor and an ambient parameters indicator

  • CO dilution to extend the sensor range up to 10%

  • The UniGas has a standard USB serial port and the configuration PC software to configure the analyzer.
  • GREENLINE 2000 / 4000 / 6000 / 8000

  • Application: Glass manufacturing companies, Industrial heating boilers, Utility / power plant boilers , Furnaces / Kiln (cement, glass, lime, ceramic, gypsum)and Dryers (paint, textile, food, paper, rubber)

  • The instrument to use will be chosen after two criteria

  • Number of sensors Up to 9 Sensors

  • Suitable for analyze O2,CO, CO2, NO, NO2, NOx, SO2, and CxHy

  • ISO14000 compliance and auditing
  • PORTABLE INFRARED THERMAL

  • Temperature Range up to 3,000°C

  • Spectral Response:1 µm, 1.6 µm, and 8-14 µm

  • Optical Resolution up to 200:1

  • Rugged with Protective Rubber Holster

  • Target Spot Size: 6mm at 1,000 mm

  • An emissivity adjustment from 0.10 to 1.00

  • A dual laser pointer defines at different distances the true target dimension.

  • High contrast custom LCD display
  • MICRORAY FOOD/PRO/HVAC/AUTO

  • Professional Infrared Thermometers

  • Comfortable: Pistol Grip

  • Measure range: -30 to 600 °C

  • Accuracy: ±1.5% rdg

  • Built-in white LED on AUTO+

  • Application: General Maintenance, High Temperature, HACCP Checks, Automotive Testing

  • Memory: last reading+ 64 mem+USB + real time clock

  • Spectral Response: ±1°C (from 0 to 100 °C)
  • ELECTRONIC STARTER FOR LOW AND MEDIUM POWER CAGE MOTOR

  • 3 available supply voltages:
    220 V - 415 V from 4 kW to 670 kW.
    500 V from 11 kW to 900 kW.
    690 V from 75 kW to 1 200 kW.

  • Starting: Ramp or constant current with or without boost. Current adjustable between 1 In and 5 In. Starting time adjustable between 1 s and 220 s.

  • Stopping: Freewheel, soft, regulated (pump), braking or emergency stop. Stopping time adjustable between 1 s and 220 s.
  • ELECTRONIC STARTER FOR LARGE POWER SLIPRING MOTOR

  • Standard starting times 20 s, 30 s, 40 s, 60 s, 80 s and 130 s

  • Electrolyte level is monitored by magnetic float switches.

  • Temperature of the electrolyte is controlled by thermostats.

  • Electrolyte cooling is controlled by natural convection assisted by an agitator.

  • Low current density in the electrodes: in the order of 1 A/cm2.

  • Control system protection: IP 54 (IP 55 in option).

  • Electrolyte cooling is controlled by natural convection assisted by an agitator

  • Contact
    Kinetics Corporation Ltd. (TIB)

    388 Ratchadapisek Road, Chandrakasem,
    Chatuchak, Bangkok 10900 Thailand.
    Tel : 662-515-8951
    Fax : 662-515-8988
    E-mail : tib@kinetics.co.th
    Website : www.kinetics.co.th