THE MET LAB@ ML-500 & ML-800 SERIES
Flow range : 0.5 to 50,000 scc/min
Accuracy : ±0.15% to 0.5% scc/min
Non-corrosive, non-condensing, non-combustible gases, less than 70% humidity
Single, Auto or User-Specified Burst
Ambient Temperature 15-30๐C
Storage Temperature 0-70๐C
Operating Pressure 15 PSI
Display Backlit LCD
THE DEFENDER TM 500 SERIES
Flow range : 5 to 30,000 scc/min
Accuracy : 1% volumetric
Broad dynamic flow range
Choice of single, hands-free continuous, or user-specified “Burst” measurements
The temperature and pressure conditions of the calibration process (520 model)
Time intervals between measurements for checking personal sampling pump stability over a typical sampling period
THE DEFINER™ 220 SERIES
Flow range : 5 to 30,000 scc/min
Accuracy : 1% Standardized , 0.75% volumetric
Organizations, ±2% or ±3% of reading standardized accuracy is no longer enough.
Accuracy of ±1% percent of reading, including temperature and pressure compensation.
Gas Compatibility : Use with non-corrosive, non-condensing, non-combustible gases, less than 70% humidity
THE DEFINER™ 1020 SERIES
Flow range : 5 to 500 sl/min
Accuracy : ± 0.25% of reading
Single, Continuous or Burst, with averaging function selectable from 1 to 100
Non corrosive, non-condensing, noncombustible gases, less than 70% humidity
Storage Temperature: 0 – 70° C
Pressure (Operating): 10 - 19.5 PSI (absolute)
INTEGRATOR TM 110 COMMAND, CONTROL AND READOUT DEVICE
Simultaneously display flow measurements, device’s readouts and deviation percentages
Works with Bios Optimizer Software, featuring automated calibrations and a comprehensive Device Under Test (DUT) database
Commands mass flow controllers to generated specific flows, while simultaneously indicating and verifying their output
generates user-entered set point for most mass flow controllers
THE DEFINER™ 110 EPA FLOW TRANSFER STANDARD
Small and lightweight, making it at home in the field, rough handling is the norm.
Direct replacement to fragile, glass-style orifice calibrators.
Compact, durable orifice is fit directly on an air sampler with a standard 1.25 inches OD inlet tube
Available in two flow ranges, The Definer 110 features an uncertainty of just 1% of flow reading within its rated flow range
GAS FLOW BENCH
Using proven DryCal® technology and DryCal® standard.
Configured to provide the stable flow critical to the calibration process.
Our configurations use different components to connect the gas source, regulate pressure, control the flow, and direct
Benches are pre-configured for specific applications. They are available in different configurations.
Contact
Kinetics Corporation Ltd. (TIB)
388 Ratchadapisek Road, Chandrakasem,
Chatuchak, Bangkok 10900 Thailand.
Tel : 662-515-8951
Fax : 662-515-8988
E-mail : tib@kinetics.co.th