AMI 300 MULTIFUNCTION
Anemometer: Vane & Hotwire
Thermometer: Type J, T, K & PT100
Manometer: : 0 to ±500, ±2,500 Pa, 0 to ±10,000 mmH2O, 0 to ±500, ±2,000 mBar & Pitot tube: 2 to 100 m/s
Hygrometer: 3 to 98%HR
Air Quality (CO/CO2): 0 to 5000 ppm
Tachymeter: 60 to 60 000 tr/min (optic) , 30 to 20 000 tr/min (contact)
Memory : up to 12 000 measurement points Data logger software for data recording and processing
SL 100 SOLARIMETER & SL 200 WITH SOFTWARE
Measurement and spot check of solar power (W/m2). Supplied with calibration certificate and transport case.
Instantaneous, average, min/max values, hold function
Spectral response from 400 to 1100 nm
Calculation of energetic exposure in Wh/m2
Results (Wh/m2) saved when instrument is switched off
Solar irrigation measuring range : 1 W/m2 to 1300 W/m2
Energetic exposure measuring range : 1 Wh/m, 2 to 500 kWh/m2
Frequency of measurement : 1/s
CR 100 SOLAR RADIATION
Applications : for QualiSOL, Quali PV certified professionals, the office control for the guarantee of Solar Result. Analogic signal 0-10V or 4-20mA proportional to solar power.
Solar irrigation measuring range : 0 W/m 2 to 1300 W/m2
Spectral response : from 400 to 1100 nm
Output / power supply : active sensor 0-10 V, power supply 24 Vac/Vdc 10%, 3-4 wires, passive loop 4-20 mA, power supply 18/30 vdc, 2 wires
Electrical connection : screw terminal bock for cable Ø 1.5 mm2 max
AQ 100 AIR QUALITY
Functions: CO2 and temperature.
CO2 : Infrared sensor.
CO2 : from 0 to 5,000 ppm
Temperature : from -20 to 80°C
Supplied with transport case and calibration certificate.
Selection of units
Minimum and maximum values
HOLD function
Adjustable automatic shut-off
Adjustable backlight
AQ 200 AIR QUALITY
Functions: air quality (CO, CO2), climatic conditions, temperature, hygrometry.
Memory: up to 8,000 measurements points
CO / temperature probe: 0 to 500 ppm, -20°C to +80°C
CO2 / temperature probe: 0 to 5000 ppm, -20°C to +80°C
CO2 / temperature / hygrometry probe: 0 to 5,000 ppm, -20°C to +80°C, 5 to 95%HR
Climatics conditions: 5 to 95%HR, -20°C to +80°C, 800 to1100 hPa
Thermometer: Type J, T, K & PT100
Current / Voltage: 0 to 2,5 V, 10 V, 4/20 mA
DBM 700 FLOW METER
Measurement range : 85 to 4,000 m3/h. Accuracy: ±3% of the reading ±10 m3/h
7 interchangeable hoods available: 500x500 mm, 600x600 mm, 700x700 mm, 400x1200 mm, 700x1200 mm, 400x1500 mm, 1000x1000 mm
Quick and simple hood changes, no disturbance to the flow.
Optional software to download the measured values to your PC for analysis.
Reliable and robust yet light and easy to handle.
LV 100 AIR VELOCITY
Functions: Vane velocity and airflow, temperature.
LV 101 - Ø 14 mm vane:
Air velocity: 0,8 to 25 m/s, Temperature: -20 to +80°C, Air flow : 0 to 99,999 m³/h
LV 107- Ø 70 mm vane:
Air velocity: 0,3 to 35 m/s, Temperature : -20 to 80°C
LV 110- Ø 110 mm vane:
Air velocity : 0,25 to 35 m/s, Air flow : 0 to 99,999 m³/h, Temperature : -20 to +80°C
Supplied with vane, transport case and calibration certificate.
LV 130 VANE PROBE THERMO-ANEMOMETER
Functions: air velocity, airflow, ambient temperature
LV 130 : rotating vane probe
LV 120 : fixed vane probe
Air velocity : from 0.25 to 35 m/s
Airflow : from 0 to 99,999 m3/h
Temperature : from 0 to +50°C
AIRFLOW CONE FOR VANE 100 MM
Air flow cone for diameter 100 mm. Vane probe.
Available in several dimensions
VT 100 ANEMOMETER
Functions: Hotwire velocity and airflow, temperature.
Air velocity : 0,15 to 30 m/s
Air flow : 0 to 99,999 m³/h
Temperature : -20 to +80°C (include in probe)
AIRFLOW CONE FOR HOTWIRE ANEMOMETER
Hotwire anemometer cones:
Cone K35 : 10 à 400 m³/h - 200 x 200 x 300 mm Cone K75 : 30 à 750 m³/h - 300 x 300 x 470 mm.
Hot wire and Vane Ø100 mm anemometers from Class 100, 200 and 300 portable instruments.
CVT 100 AIR VELOCITY
Measuring ranges : from 0-5 m/s to 0-30 m/s and from 0 to +50°C, -20 to +80°C
0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires)
Probes : remote or duct mount
Housing : ABS - IP 65
Display : with or without 5-digits
LCD Software or DIP switch configuration
Alternating display of air velocity and temperature
Mounting with the 1/4 turn system with wall-mount plate
CVT 200 AIR VELOCITY
Measuring: from 0-1 m/s to 0-20 m/s and 0 to +50°C.
Configurable intermediary and central zero ranges.
Simultaneous display of 2 parameters
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software or DIP switch configuration
ABS - IP 65 housing, with or without 2-line backlit display
Mounting with the 1/4 turn system with wall-mount plate
CVT 300 AIR VELOCITY
Measuring: from 0-1 m/s to 0-30 m/s and 0 to +50°C.
Configurable intermediary and central zero ranges.
Interchangeable measurement probe
Simultaneous display of 4 parameters
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software or DIP switch configuration
ABS - IP 65 housing, with or without 2-line backlit display
Mounting with the 1/4 turn system with wall-mount plate
EHK 500 HUMIDITY BENCH
Applications: The EHK 500 is an electronic portable device for adjusting humidity and temperature sensors via a single RS232 connection.
Measuring range : 0-100 %RH
On site calibration: time saving, no need to return the transmitter to our After sales-service. You can adjust yourself.
The transmitter is always ready-for-use
Display : with or without 5-digits
LCD Software or DIP switch configuration
Mounting with the 1/4 turn system with wall-mount plate
HUMIDITY, TEMPERATURE SPECIAL FOOD INDUSTRY
Relative humidity, dew point and ambient temperature
Humidity
Relative humidity, dew point and temperature. HACCP principale
Humidity: 5 à 95 %RH
Temperature: -20 to +80°C
Dew point: -40 to +80°Ctd
TEMPERATURE
Thermometer: Type J, T, K & PT100
LX 100 & LX 200 LUX METER
For workstations, offices, sport installations, parking, commercial centers
Dedicated to control and monitoring luminance.
Adjust contrast and activate backlight
Remind last checking date
LX 100 range: 0,1 to 150 000 lux (from 0,01 to 13940 fc).
LX 200 range: 0.1 to 200,000 lux. With its memory, it allows storage of measurement cessions for processing on a computer thanks to the LLX200 software.
HD 100 HYGROMETER
Functions: Relative humidity, dew point and temperature.8,000 measuring points DATALOGGER software (option)
Relative humidity: from 5 to 95%HR
Temperature: -20 to +80°C
Dew point: from -20 to +80°Ctd
Selection of units (temperature and dew point)
HOLD function, Minimum and maximum values
Adjustable automatic shut-off
Adjustable backlight
HD 200 HYGROMETER
Functions: Relative humidity, dew point and temperature. 8,000 measuring points DATALOGGER software (option)
Relative humidity: from 3 to 98%HR
Absolute humidity: from 0 to 285g/Kg
Dew point: from -50 to +80°Ctd
Thermometer: Type J, T, K & PT100
Current / Voltage: 0 to 2,5 V, 10 V, 4/20 mA
Interchangeable measurement modules
User-friendly (Joystick navigation)
Large graphic display
HM 100 PIN MOISTURE METER
Humidity percentage measure of wood, concrete, plaster and bricks.
Softwood : from 10 to 93.7 %
Harwood : from 8 to 78.5 %
Concrete and plaster : from 1 to 2.5 %
Bricks : from 0 to 22.9 %
Minimum and maximum values for each type of material
Protection cap and auto-test
Material resistance can provide a direct measurement of present moisture with the help of a given scale.
DB 100 & DB 200 SOUND LEVEL METER
DB 100 parameters : LAFmax, LAFmin, LASmax, LASmin
Measuring range : 30-130 dB, Resolution : 0,1 dB
Measured parameters : LA et LAeq
DB 200 Measured values : L, Leq, LE, Lpk.
Measurement dynamic: Lp/Leq: 100 dB - Lpk: 50 dB
A-weighted measurement range: 30-130 dB
C-weighted measurement range: 35-130 dB
Z-weighted measurement range: 35-130 dB
Peak channel measurement range: 83-133 dB
CT 100 OPTICAL (O) & CT 100 CONTACT (C)
Functions : optical or contact tachometry
CT 100 O Measuring range: From 60 to 60,000 tr/min Supplied with optical probe, transport case and calibration certificate.
CT 100 C Measuring range: From 30 to 20,000 tr/min Supplied with optical probe and ETC adaptor, transport case and calibration certificate.
Selection of units, HOLD, Minimum and maximum values
Choice between optical and contact revolution counter
ATE 300&ATT 300 MULTI-CHANNEL DISPLAYER
1 RS 232 digital input KIMO external transmitter (class 200 & 300)
1 RS 485 digital input/output (Modbus protocol integrated)
22 pre-set units and 3 configurable units
ATE 300 can display 3 parameters (for example humidity, temperature and pressure). Can be installed flush-mounted or wall-mounted.
ATT 300 can work with any current or voltage input of any transmitter : pressure, humidity, temperature, airflow, air velocity
MP 100, 101, 105, 112 & 120 MANOMETER
Functions: Pressure, differential pressure, manual auto calibration, Hold function, min/max. Values.
MP 100 : 0 to ±1,000 Pa
MP 101 : 0 to ±1,000 mmH2O
MP 105 : 0 to ±500 mBar
MP 112 : 0 to ±2,000 mBar
MP 120 : 0 to ±1,000 Pa and from 2 to 40 m/s
Adjustable climatic parameters (MP120)
Built-in calculation for velocity (MP120)
MP 130 MANOMETER FOR GAS NETWORK SEALING
For gas network sealing control.
Functions: Pressure, self-calibration.
Measuring range from 0 to ±200 mbar.
Supplied with sealing kit, transport case and fitting certificate.
Straight connection for Ø 5 x 8 tubes.,T-connection for Ø 5 x 8 tubes.,Y-connection for Ø 5 x 8 tubes.
MP 200 MANOMETER
Functions : Pressure, Velocity, Airflow, Air quality (CO/temperature).8, 000 measuring points
Pressure: 0 to ±500, ±2,500 Pa, 0 to ±10,000 mmH2O 0 to ±500, ±2,000 mBar & Pitot tube: 2 to 100 m/s
Thermometer: Type J, T & K
CO / temperature probe: 0 to 500 ppm, -20°C to +80°C
CO2 / temperature probe: 0 to 5000 ppm, -20°C to +80°C
CO2 / temperature / hygrometry probe: 0 to 5,000 ppm, -20°C to +80°C, 5 to 95%HR
Current / voltage 0 to 2,5 V, 0 to 10 V, 0 to 4/20 mA
KIRAY 50, 100, 200, 300 INFRARED THERMOMETER
KIRAY 50 Temperature range : From -50 to +380°C
KIRAY 100 Temperature range: From -50 to +800°C
KIRAY 200 Temperature range: From -50 to +850°C
KIRAY 200 Temperature range: From -50 to +1850°C
Dual laser sighting : wave length : from 630 nm-670 mm
A key tool to measure surface temperatures of hot objects, dangerous or difficult to access
For kiray Wide range of Thermocouple K temperature probes :Ambient, contact, penetration, general use
MANOMETER DFP SERIES, REFERENCE STANDARD
Range : 0-3600, 0-5600, 0-18600 Pa Detection on 3 levels : high, low, exact with 3 LED’s
Resolution : ±0,01 mm or 0,0005 inch. Accuracy : 0,2% of the reading ± 1 Pa between 0 and 3000 Pa / ± 0,5% of the reading ± 2 Pa between 3000 and 20000 Pa. Detection sensitivity : < to 0,03 mm. Operating temperature : 15 to 25 °C. Operating maximum relative humidity : 70% HR.
MANOMETER-INCLINED, VERTICAL
For high differential pressure with compact sizes
0 to 100 mmH2O to 0-2, 6 bar.
Direct reading or reading by column addition.
Units : mmH2, DaPa, mabr ...
For very low differential pressure
0-5 to 0-100 mmH2.
Centre 0 scale.
Units : mmH2 Pa, DaPa...
Contact
Kinetics Corporation Ltd. (TIB)
388 Ratchadapisek Road, Chandrakasem,
Chatuchak, Bangkok 10900 Thailand.
Tel : 662-515-8951
Fax : 662-515-8988
E-mail : tib@kinetics.co.th